HAZTEC FR Workwear Brochure V2.5 - Flipbook - Page 9
LAYERING GUIDE
UNDERSTANDING TEST METHODS & RESULTS
There are Test Methods and Test Results for ARC Flash Clothing.
Here we provide a basic overview of the methods used for HAZTEC
Workwear and the resulting data.
ABOUT LAYERING
BOX TEST METHOD
When garments are tested using the Box Test method
an ARC rating of either Class 1 or Class 2 is achieved.
Adding a Class 1 garment with another class 1 garment
does not necessarily give you a Class 2 rating and
the combined result can only be confirmed when the
garments are tested together.
Outer Layer
(JACKET, 9,6cal/cm2)
OPEN ARC METHOD
ATPV or EBT ratings - when garments are tested
using this method a rating per garment is achieved.
When worn in combination with other garments,
these ratings can be added together (as a guide to
some degree) but the total protective value of the
combination is only known when the garments are
tested as a combined set.
Mid Layer
(POLO SHIRT,4,6cal/cm2)
Base Layer
(BASELAYER, 6 cal/cm2)
WEARING OF NON-ARC CERTIFIED
GARMENTS WITH YOUR ARC GARMENTS
Total
34,0cal/cm2
OUTER LAYERS
It is important to remember that the outermost layer
of your protective clothing must be FR and ARC rated.
To add a non-FR layer over your ARC rated garments
defeats the whole purpose of wearing ARC rated
garments – if that outer layer was to ignite, the heat
can transfer through your inner ARC garments to your
body.
GAPS BETWEEN YOUR GARMENTS
ALLOW AIR FLOW BETWEEN LAYERS
INNER LAYERS
Wearing non-ARC rated garments beneath your
ARC rated garments can also be the cause of serious
burn injuries. We recommend that if non-ARC rated
undergarments are worn that these are natural
non-melting fibres e.g. 100% cotton. Polyester type
fibres or similar fabrics that can melt should not be
worn if there is a flame, heat or ARC hazard present in
your workplace as this can cause serious burn injuries.
*figures shown are indicative
Aberdeen: +44 (0)1224 707468
9