HAZTEC FR Workwear Brochure V2.5 - Flipbook - Page 8
ABOUT ARC FLASH TESTING
ARC TESTING METHODS
There are two test methods for ARC Flash protective
clothing under IEC 601482:
IEC61482-1-2 COMMONLY KNOWN
AS THE ‘BOX TEST’
The Box Test method gives a protective classification
of either APC 1 Class 1, 4KA (lower level of protection) or
APC 2 Class 2, 7KA (higher level of protection). This has
traditionally been the popular and most recognised standard
in Europe.
IEC61482-1-1: COMMONLY KNOWN
AS THE ‘OPEN ARC TEST’
HAZTEC® BREGA FR AS ARC Hi-Vis Polo Shirt. ARC Flash
tested using the Box Test method.
The open ARC test method gives an ARC Thermal
Protective Value (ATPV) rating or an energy break open
threshold (EBT50) rating. This is becoming increasingly
popular as garment combinations certified to this method
can give figures that are more relevant in risk assessments or
ARC Flash calculations. For workwear within the HAZTEC®
product range, a single layer garment that is sold with an
ARC certification is commonly certified to Class 1 on
the Box Test method, or it will have an ATPV value.
ABOUT ELIM (Energy Limit Value)
ELIM is the figure that will become the recognized value
that will be used. Larger electrical organizations where Arc
Flash Hazards are a daily risk will already be specifying this
figure. In the interim period it is important to be aware that
comparisons could be made between an ATPV and an ELIM
figure, of which ELIM will always be lower.
ELIM has been introduced because the opinion of EU
was that 61842-1-1 could be in conflict with EU directive.
According to directive, no standard can impose harm to a
worker.
By this, ATPV/EBT imposes 50% probability that a worker
will sustain second degree burn in electric arc exposure.
This means that the worker will statistically have burns every
other time.
ELIM is the conservative calculation of risk of an electric
arc. ELIM the maximum incident energy that a protective
clothing can prevent against in a hazardous situation,
with 0% probability of enough energy getting through the
garment to cause a second-degree burn.
HAZTEC® BAKKEN
OPEN ARC FLASH TEST
HAZTEC® MERCURY FR AS ARC Hi-Vis Jacket ARC Flash
tested using the Open Arc test method and certified with both
a ATPV and ELIM value.
KEY TERMINOLOGY - IN SUMMARY
TEST METHOD
The type of ARC flash test applied to the garment. Either the
Box Test (often used in Europe) or the Open Arc Test (common
in the US but is our preferred test method on HAZTEC®
workwear.)
4kA/7kA
The test data results from a Box Test, now also known as APC 1
and APC 2.
ATPV RATING
The most common test result from an Open Arc Test, provided
as a calorific value.
SCAN HERE
TO WATCH
ARC FLASH
TESTING
VIDEOS
ELIM RATING
HAZTEC® ORWELL
OPEN ARC FLASH TEST
8
The figure to watch out for moving forward and featured on
HAZTEC® garments. Often a lower calorific value but a safer
figure. This is the value at which there is a 0% probability of
second degree burns versus the ATPV value which is a 50%
probability of second degree burns.
HAZTEC® Workwear, T: +44 (0)1280 841400,W: haztecworkwear.com