HAZTEC FR Workwear Brochure V2.5 - Flipbook - Page 46
EN/UK STANDARDS EXPLAINED
IEC 61482-2:
2009
EN ISO
11612
IEC 61482-2:
2018
EN ISO 11612
IEC 61482
CLOTHING TO PROTECT AGAINST HEAT AND
FLAME
PROTECTIVE CLOTHING AGAINST THE
THERMAL HAZARDS OF AN ELECTRIC ARC
This EN Norm specifies PPE clothing for use when working
where this is a risk that the garments will come into contact
with heat and flame. It is divided into different categories where
code letters (A, B, C, D, E and F) indicate which heat and flame
requirements the garment needs to fulfil. These code letters
represent hazards including radiant heat, convective heat and
splatters of molten metal or aluminium. Code A1 and/or A2 is
mandatory, and a minimum of 1 other letter is required in order to
CE mark the garment. The code letters are classified at different
levels where the highest number is the highest tested level.
The design of the garments is also a critical factor in garments
certified to these EN Norms.
PPE Regulation Type: Category III
EN 1149-5:
2008
PPE certified to this standard is for use where there is a risk of an
Electric Arc, most commonly where working with electricity on
open equipment or maintenance and switching work. Whilst this
traditionally has been regarded as work in dedicated electrical
environments, many companies now recognise that this risk can
occur in many other industrial environments including general
groundworks and industrial maintenance. There are requirements
not only in the fabrics used but in the Design and Construction of
garments certified to this standard.
EN ISO
14116
EN 1149-5: 2008
EN ISO 14116
PROTECTIVE CLOTHING WITH
ELECTROSTATIC PROPERTIES
LIMITED FLAME SPREAD
This is the European Standard for garments that protect against
electrostatic discharge in areas where there is a risk of explosion
(e.g. ATEX Environments) where there is a risk that the garments
could create sparks (source of ignition), which in turn could
ignite explosive materials. Typical environments would include
petrochemical refineries and fuel distribution companies.
Annex II, art. 2.3. of the ATEX directive 99/92/CE concerning
the protection of workers likely to be exposed to the risk of
explosive atmospheres says: “Workers must be provided with
appropriate working clothing consisting of materials which do
not give rise to electrical discharges that can ignite explosive
atmospheres”.
46
This European Norm is often used for lower-level Flame
Resistant protective garments such as socks, rainwear and
hi-visibility waistcoats. It is divided into 3 classes, where index 3
is the highest.
The flame does not spread, there is no flaming debris, nor
afterglow, a hole may be formed. The flame does not spread,
there is no flaming debris, nor afterglow, no hole formation.
The flame does not spread, there are no flaming debris, nor
afterglow, no hole formation, the after-flame times of each
individual specimen is less than 2 seconds. It is important to
note that Index 3 garments should be worn in conjunction with
EN ISO 11612 garments, and Index 1 garments should not be
worn next to the skin.